**** WE ARE CURRENTLY RUNNING APPROXIMATELY 2 TO 3 WEEKS OUT FOR PROCESSING AND PACKING **PLEASE REMEMBER THAT SHIPPING TIMES YOU ARE QUOTED AT CHECK OUT ARE TRANSIT TIMES ONLY (how long it should take to get to you once the carrier has picked up your package), THIS DOES NOT INCLUDE PROCESSING AND PACKAGING TIME**. As always we thank you for your business and your patience. 9/14/26 Dismiss
Skip to content$89.07 $89.07
2 in stock
$320.15 $320.15
Out of stock
$137.16 $137.16
Out of stock
$379.25 $379.25
Out of stock
$182.68 $182.68
Out of stock
$14.61 $14.61
2 in stock
$69.32 $69.32
3 in stock
$205.43 $205.43
Out of stock
$306.14 $306.14
Out of stock
$302.33 $302.33
Out of stock
$164.28 $164.28
$252.61 $252.61
5 in stock
$29.50 $29.50
1 in stock
$233.33 $233.33
Out of stock
$100.39 $100.39
$240.16 $240.16
Out of stock

Coleman Evcon furnaces vary by series, year, and EB configuration. Our staff can cross-reference your model number to the correct part before you order. Three minutes on the phone can prevent a $200 mistake.

We have been selling parts specifically for manufactured and mobile homes since 1994. Not HVAC in general. Manufactured homes specifically. That focus shows in the inventory we carry and the guidance our staff gives.

Call any of our 7 North Carolina locations and speak with someone who knows Coleman Evcon units. Not a call center. Staff trained specifically in manufactured housing parts and model compatibility.

Genuine Coleman OEM parts sit alongside tested OEM-compatible replacements. You get the right component at the right price without hunting across multiple suppliers for the same furnace.

A wrong part does not just waste money. It wastes the days you spend diagnosing, waiting on a return, and sitting without heat. Here is what determines whether the part you order will actually work in your unit.
Coleman Evcon uses multiple variants of the same component across different EB series models. A limit switch from one model will not always seat or wire correctly in another. Always confirm the part number on the component coming out before ordering a replacement.
OEM parts are manufactured to Coleman’s exact specifications. OEM-compatible parts meet the same operational specs and fit the same mounting positions. For most homeowners, an OEM-compatible part at a lower price point performs identically in normal residential use. If your unit is under warranty, confirm with your warranty provider before installing non-OEM parts.
The limit switch is the most replaced component in Coleman Evcon electric furnaces. It trips when the furnace overheats and sometimes sticks open after repeated cycling. If your furnace runs but produces no heat, or shuts off after two minutes, the limit switch is the first part to check.
An electric furnace that takes too long to heat up, or only heats partially, often has a failed sequencer. Coleman Evcon units use two and three-stage sequencers, depending on the model. Ordering the wrong stage count means the furnace will not operate on its full heating cycle.
The flame sensor is only present in gas-fired Coleman Evcon models. If your furnace ignites, runs for 30 seconds, and then shuts off, a dirty or failed flame sensor is the likely cause. Pro tip: A dirty sensor can sometimes be cleaned with fine steel wool. However, because it is an inexpensive under-$20 part, most Coleman owners replace it outright during a troubleshooting session rather than risking a second system lockout a week later. Fresh part, problem solved.
Coleman Evcon flue assemblies are model-specific. Before ordering, confirm whether your furnace uses a horizontal or vertical flue run and the diameter of your existing vent pipe. Installing a flue assembly sized for a different configuration creates a combustion exhaust risk. If you are not certain of your venting configuration, call us before ordering. Our staff can walk you through what to look for.
HVAC parts cannot be returned once ordered. These four checks take ten minutes. None of them are complicated.

The model number is on the rating plate inside the furnace cabinet door. (Look for a silver or white metal decal. It's usually located on the interior right-hand wall or behind the removable front panel). Coleman Evcon uses similar-looking components across different series that are not cross-compatible. Without it, you are guessing. Write it down before you open a product page.
Every Coleman Evcon component has a stamped or printed part number on the body of the part itself. That number is the most reliable matching point. If the part is physically damaged and the number is gone, call us with your model number and we can cross-reference the correct replacement.
It helps to know what the furnace is doing before it fails, not just that it failed. Clicks but does not ignite. Runs for two minutes and shuts off. Blows air, but no heat comes through. Each symptom points to a different component. Not certain which part is failing? Our how-to guides walk through common Coleman Evcon repairs, or call our staff, and we will narrow it down before you order.
To ensure sensitive electrical components are never pre-installed or compromised, opened HVAC items cannot be returned. This policy guarantees that every component shipped to your door is 100% factory-tested and pristine.
On a gas Coleman Evcon, clicking without ignition usually points to either the igniter or the flame sensor. If the furnace clicks repeatedly and then shuts off with no flame, the igniter is trying to fire but failing. If the furnace ignites briefly and then cuts out within 30 seconds, the flame sensor is not detecting the flame and killing the gas supply as a safety measure. Both parts are stocked here. Confirm with your model number before ordering.
On an electric Coleman Evcon, cold air with the blower running usually means a failed sequencer or a tripped limit switch. The sequencer controls when the heating elements fire. A limit switch that is stuck open prevents the elements from energizing at all even though the blower operates normally. Check the limit switch first since it is the less expensive part.
Open the furnace cabinet door. The rating plate is attached to the inside of the cabinet, usually on the right wall or the back panel. The model number begins with EB for electric furnace units or with a different prefix for gas models. Write down the full string including all letters and numbers. That full number is what you need to match parts accurately.
Not always. Coleman Evcon manufactured home furnaces use components specific to their model series and wiring configurations. Some components share part numbers with residential Coleman units and some do not. Always confirm the part number from your specific unit rather than assuming cross-compatibility from the brand name alone.
HVAC parts cannot be returned once opened. If the part was shipped incorrectly or arrived defective, report it within 10 days without installing it and we will resolve that situation. For all other cases, confirm your part number before ordering. Review our full returns and refunds policy before placing your order. Call 1-800-368-6208 before adding to cart if you are not certain. A wrong part is not returnable.
Yes. We stock OEM parts manufactured to Coleman’s original specifications alongside OEM-compatible replacements that meet the same operational and fit requirements. For most manufactured home repairs, an OEM-compatible part performs identically in everyday use. If your unit is under an active warranty, check your warranty terms before installing a non-OEM component.
Standard shipping can take time due to high demand. However, we carry core Coleman Evcon parts at our 7 North Carolina locations for same-day pickup. If you are freezing and cannot wait for a carrier, call us now to check whether your part is sitting on the shelf in Fayetteville or Goldsboro. See full shipping timelines at our shipping policy.

Powered by WooCommerce Checkout On Popup Plugin from WPSuperiors
Powered by WooCommerce Checkout On Popup Plugin from WPSuperiors